Home > Products > Construction Doors > Fireproof Doors > Fireproof Door EI₂30
Steel profile fire- and smoke resistant doors are used for fire compartment sections in industrial, residential and office buildings, where the fire door must meet the required resistance class.
The fire resistance of the doors is certified in accordance with the EN 16034 standard.
Other parameters of the doors are assessed in accordance with the requirements of the EN 14351 series of standards.
The product complies with Swedish type approval documentation 0336/03 (RISE).
Smoke resistance Sa/S200, fire resistance E30, EI₂30.
It is possible to add various properties (soundproofness, burglary resistance, external door properties etc.). For more detailed information, please contact Tammer’s sales department.
The dimensions and shape of the EI₂30 fireproof profile door and glass slats are generated according to the customer’s needs and production capacity. For more detailed information, please contact Tammer’s sales department.
The products are made of steel profiles of the SP500 series (sometimes SP700), which are made of unprocessed, galvanized or acid-resistant stainless steel EN 1.4404 (ASTM 316L, SS 2348).
Glass slats are made of galvanized or stainless steel and are fixed with hidden or through screws. Glass slats come in different widths to accommodate glass of different thicknesses and fireproof properties.
The depth of the frame depends on the used profile series and is usually from 50mm to 90mm.
Door set can be powder or wet painted in different RAL colors or have stainless steel brushed or polished finish.
The door can be fitted with different mechanical locks and door closer systems.
Metal door is intended for indoor and outdoor use in both residential and public buildings,
where the fireproof and/or evacuation requirements are stated.
Fire resistance of the doors is certified in accordance with standard EN 16034.
Other parameters are assessed in accordance with the requirements of the EN 14351 standard series.
MEASUREMENTS AND PROPERTIES OF A SINGLE-LEAF DOOR
Max measurements | 1357x2518mm, max 3,10m2 |
Weight of a door leaf | 33kg/m² |
Fire resistance | E120, EW60, EI₂30 (EN 13501-2) |
Smoke resistance | Sa/S200 (EN 13501-2) |
Sound resistance | up to 37dB (ISO 717) |
Thermal conductivity | 0,94-1,3 W/m²K (ISO 12567, ISO 10077) |
Burglar resistance | RC2, RC3 (EN 1627) |
Watertightness | class 6A (EN 12208) |
Resistance to wind load | class C3 (EN 12210) |
Mehchanical strength | class 3 (EN 1192) |
Air permeability | class 4 (EN 12207) |
Resistance to repeated opening and closing | class 8 (EN 12400), C5 (EN 13501-2) |
The exact value of the characteristics above depends on the parameters of the door being
projected.
MEASUREMENTS AND PROPERTIES OF A DOUBLE-LEAF DOOR
Max measurements | 1357x2518mm, max 3,10m2 |
Weight of a door leaf | 33kg/m² |
Fire resistance | E120, EW60, EI₂30 (EN 13501-2) |
Smoke resistance | Sa/S200 (EN 13501-2) |
Sound resistance | up to 37dB (ISO 717) |
Thermal conductivity | 0,94-1,3 W/m²K (ISO 12567, ISO 10077) |
Burglar resistance | RC2, RC3 (EN 1627) |
Watertightness | class 6A (EN 12208) |
Resistance to wind load | class C3 (EN 12210) |
Mehchanical strength | class 3 (EN 1192) |
Air permeability | class 4 (EN 12207) |
Resistance to repeated opening and closing | class 8 (EN 12400), C5 (EN 13501-2) |
The exact value of the characteristics above depends on the parameters of the door being
projected.
The door can be fitted with different mechanical locks and door closer systems.
For more detailed information, please contact Tammer’s sales department.
Door set can be powder or wet painted in different RAL colors or have stainless steel brushed or polished finish. PVC covered steel and laminate can be used.