EMI Shielding Door SMU101

Areas of use

The EMI Shielding metal door is used in EMI/RFI (electromagnetic interference and radio frequency interference) shielding, security, and server rooms, where sensitive electronic equipment needs to be isolated from surrounding electromagnetic fields and signals.

The required protection is ensured only if the wall, ceiling, and floor are also equipped with appropriate radiation shielding, and the door is installed by a qualified specialist.

The product complies with the EN 14351-2 or EN 14351-1 standard and has been tested in accordance with EN 50147-1, in the frequency range from 100 MHz to 10 GHz.

Features

Door Type Type/Class Level / EMI Shielding Effectiveness
SMU 101 EI60 EMI Class I Professional Use AAA 50dB≥>40dB (Test result: 61dB≥>43dB)
SMU 101 EI60 45dB EMI Class I Professional Use AAA 50dB≥>40dB (Test result: 77dB≥>45dB)
SMU 101 EI60 45dB Class II General Use AAA 20dB≥>10dB (Test result: 29dB≥>14dB)

EMI shielding effectiveness of the product in dB.

The product can be supplemented with various additional features such as sound insulation, smoke protection, fire resistance, burglary and bullet resistance, explosion resistance, and more.
For more detailed information, please contact Tammer’s sales department.

Finishing

Door set can be powder or wet painted in different RAL colors or have stainless steel brushed or polished finish.

Extras

The door can be fitted with different mechanical locks and door closer systems.