Areas of use
Metal door is intended for indoor and outdoor use in both residential and public buildings, where the fireproof and/or evacuation requirements are stated.
Fire resistance of the doors is certified in accordance with standard EN 16034. Other parameters are assessed in accordance with the requirements of the EN 14351 standard series.
Features
Fire resistance: E60, EW60, EI₂30 (EN 13501-2)
Smoke resistance: Sa/S200 (EN 13501-2)
Thermal conductivity: 0,94-1,3 W/m²K (ISO 12567, ISO 10077)
Burglar resistance: RC2, RC3 (EN 1627)
Watertightness: class 5A (EN 12208)
Resistance to wind load: class C2 (EN 12210)
Mechanical strength: class 3 (EN 1192)
Air permeability: class 4 (EN 12207)
Resistance to repeated opening and closing: class 8 (EN 12400), C5 (EN 13501-2)
*The exact value of the characteristics above depends on the parameters of the door being
projected.
Dimensions
Max measurements: EW60, EI₂30 2180x2240mm, max 4,88m2
Max measurements: E60 2507x2576mm, ax 5,86m2
Weight of a door leaf: 33kg/m²
Finishing
Door set can be powder or wet painted in different RAL colors or have stainless steel brushed or polished finish. PVC covered steel and laminate can be used.
Extras
The door can be fitted with different mechanical locks and door closer systems.