Areas of use
Metal door is intended for indoor and outdoor use in both residential and public buildings, where the fireproof and/or evacuation requirements are stated.
Fire resistance of the doors is certified in accordance with standard EN 16034.Other parameters are assessed in accordance with therequirements of the EN 14351 standard series.
Features
Fire resistance: EW60, EI₂120 (EN 13501-2)
Smoke resistance: Sa/S200 (EN 13501-2)
Sound resistance: 39-45dB (ISO 717)
Thermal conductivity: 0,75-1,0 W/m²K (ISO 12567, ISO 10077)
Burglar resistance: RC4 (EN 1627)
Resistance to wind load: class C3 (EN 12210)
Resistance to repeated opening and closing: class 6 (EN 12400), C5 (EN 13501-2)
Air permeability: class 4 (EN 12207)
The exact value of the characteristics above depends on the parameters of the door being projected.
Dimensions
Max measurements: EW60, EI₂120 2392x2518mm, max 5,47m2
Weight of a door leaf: 52kg/m²
Finishing
Door set can be powder or wet painted in different RAL colors or have stainless steel brushed or polished finish. PVC covered steel and laminate can be used.
Extras
The door can be fitted with different mechanical locks and door closer systems.